We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies.
A revolutionary pocket-sized 6 channel vibration meter system for hand arm and whole body vibration allowing for measurement of both hands or tri-axial seat transmission.
Please Note - This product is available for UK orders only
Measurement | Whole Body Vibration, Hand Arm Vibration |
---|---|
Brand | Svantek |
Available Outside the UK? | No |
Human vibration measurement has never been easier with this hand arm and whole body system. Along with the SV106 six channel human vibration meter and analyser this measurement system can simultaneously measure vibration levels for both hands or tri-axial SEAT transmission.
Using the computational power of a digital signal processor the SV106 can measure real-time single and third octave levels along with the required vibration measurements for ISO 2631 and ISO 5349, including RMS, Peak, Peak to Peak, VDV, MTV, A(8) and Dose, with all required weighting filters and band limiting filters for HVM measurements.
Built in 16MB non-volatile memory and additional slot for an external Micro SD card (kit is supplied with a 4GB card) can record data for time history logging and time domain signal recording. Results and data can then be easily downloaded to a PC for for analysis. The PC software can even be used to set up the vibration meter prior to use.
Using the SV38V vibration seat pad makes whole-body vibration measurements easier and can be placed directly on a seat cushion, a floor or fixed to the back of the seat.
The SV105 tri-axial accelerometers enable easy measurement of hand-arm vibration regardless of the tool being used. The alternative SV150D triaxial accelerometer is designed for easy direct attachment to tools and equipment being measured.
The six channel dual input meter allows for 2 x SV105 or SV150D tri-axial accelerometers to be used to measure both hands simultaneously. Using a combination of 1 x SV150D accelerometer and 1 x SV38V seat pad accelerometer is also possible providing simultaneous Hand-arm and Whole Body measurements.
Please Note - This product is available for UK orders only
<
Standards | ISO 8041:2005, ISO 2631-1,2&5, ISO 5349 |
Meter Mode | RMS, VDV, MTVV or Max, Peak, Peak-Peak, Vector, A(8), Dose, ELV, EAV Simultaneous measurement in six channels with independent set of filters and detector constants |
Filters | Wd, Wk, Wm, Wb (ISO 2631) and Wh (ISO 5349) and Band Limiting filters |
RMS and RMQ Detectors | Digital true RMS & RMQ detectors with Peak detection, resolution 0.1 dB Time constants from 100 ms to 10 s |
Data Logger | Time-history data including meter mode results and spectra (option) |
Time Domain Recording | Simultaneous x, y, z time-domain signal recording, sampling frequency selectable: 375 Hz, 3 kHz or 6 kHz (option) |
Analyser | 1/1 octave real-time analysis with centre frequencies from 0.5 Hz to 2000 Hz 1/ octave real-time analysis with centre frequencies from 0.4 Hz to 2500 Hz |
Measurement Range | Transducer dependent: 0.01 ms2 RMS ÷ 50 ms2 Peak (with SV 38V and Wd filter) 0.1 ms2 RMS ÷ 5000 ms2 Peak (with SV105A and Wh filter) |
Frequency Range | 0.1 Hz ÷ 2000 Hz |
Input | 2 x LEMO 5-pin: six channels IEPE type or Direct and two channels for force transducers |
Dynamic Range | 90 dB |
Force Range | 0.2 N ÷ 100 N (dedicated channels for force transducers) |
Sampling Rate | 6kHz |
Memory | Internal 16 MB non-volatile memory Micro SD flash card slot |
Interfaces | USB 1.1 Client, Extended I/O - AC output (1 V Peak) or Digital Input/Output (Trigger - Pulse) |
Power Supply | Four AA batteries (alkaline) - operation time > 12 h (6.0 V / 1.6 Ah)2/ Four AA rechargeable batteries (not included) - operation time > 16 h (4.8 V / 2.6 Ah)2 USB interface - 500 mA HUB |
Environmental Conditions | Temperature from -10°C to 50°C/ Humidity up to 90% RH, non-condensed |
Dimensions | 140 x 83 x 33 mm (without accelerometer) |
Weight (Approx) | 390 grams including batteries (without accelerometer) SV105A Accelerometer |
Performance | Number of axis: 3 Sensitivity (± 5 %): 10.2 mV/(m/s2) at 15.915 Hz, HP1 |
Measurement Range | 0.024 ms-2 RMS,Wh ÷ 180 ms-2 PEAK |
Frequency Response (± 3 dB) | 1 Hz ÷ 2763 Hz |
Resonant Frequency | 5.5 kHz (MEMS transducer) |
Electrical Noise | < 240 µV RMS, Wh weighting, < 2.2 mV RMS, HP1 weighting |
Electrical | Supply current: < 5,0 mA |
Supply Voltage | 5.2 V ÷ 16 V Bias voltage (IEPE): 2,5 V ± 0.05 V |
Output Impedance | 51 Ω Charge / discharge time constant (start-up time): 30 sec. typ. TEDS memory: installed (power supply pin) |
Environmental Conditions | Maximum vibration: 980 m/s2 shock survival for MEMS sensor |
Temperature Coefficient | <+0.012 dB/°C/ Temperature: from -10°C to +50°C |
Humidity | up to 90 % RH, non-condensed |
Physical | Sensing element: MEMS |
Cable | integrated 1.4 meters long |
Connector | LEMO 5-pin plug (GA2007 compatible) |
Dimensions | 69.6 mm x 31.4 mm dimension; thickness from 8.3 mm to 15 mm |
Weight | 50-60 grams (including cable and one of vibration contact adapters) |
This Kit Includes: