SKU
06SV958A

Svan 958A Class 1 Four-Channel Sound and Vibration Analyser

Add to Wish List Email to a Friend

This is the Svan 958A Class 1 Four-Channel Sound and Vibration analyser which is dedicated for all applications that require simultaneous class 1 sound and vibration assessments.

Each of the four input channels can be independently configured for sound or vibration detection with different filters and RMS detector time constants which gives users an enormous measurement flexibility.

**We are only able to sell this product within the UK**

US$5,684.27
Add to Compare

Product Specification unless deselected above

More Information
Brand Svantek
Available Outside the UK? No

Svan 958A Sound and Vibration Analyser

This is the Svan 958A Class 1 Four-Channel Sound and Vibration analyser which is dedicated for all applications that require simultaneous class 1 sound and vibration assessment. Each of the four input channels can be independently configured for sound or vibration detection with different filters and RMS detector time constants which gives users an enormous measurement flexibility.

A real advantage of this instrument is the capability to perform advanced analysis simultaneously to the level meter mode. This allows the user to obtain broadband results such as Leq, RMS, LMax, LMin, LPeak together with four-channel analysis like FFT or octave band analysis.

Available analyser functions include FFT, 1/1 or 1/3 octave, cross spectra, sound intensity, RT60 and more.

There is 4-channel time-domain signal recording to .wav format as well as an exceptional feature. All of the measurement results are stored in a non-volatile 32 MB internal memory or a USB memory stick and they can be easily downloaded to a PC with SvanPC++ software. It can be offered with GPRS modem or LAN and WLAN connection module.

These interfaces provide easy remote access to instrument settings and data over Internet and local area network together with SvanPC++ RC remote communication software. It is powered from four AA standard or rechargeable batteries as well as from the external DC power source or USB interface. There is a robust case and lightweight design which accomplish the exceptional features of this new generation instrument.

Features:

  • Four channels sound or vibration configurable
  • Human Vibration measurements meeting ISO 8041:2005 including VDV and MTVV
  • Sound level meter Class 1, IEC 61672
  • Advanced data logger including spectral analysis
  • USB memory stick providing almost unlimited logging capability
  • Advanced trigger and alarm functions
  • USB 1.1 Client and USB Host interfaces
  • RS 232 for modems support (GPRS, Ethernet, WLAN)
  • Powered by four AA standard or rechargeable batteries
  • Easy in use, hand held, light weight and robust

Analyser Options:

  • FFT analysis up to 1600 lines in 20 kHz band
  • 1/1 and 1/3 octave real-time analysis
  • Time-domain signal recording
  • Sound intensity
  • FFT cross spectra
  • RT 60 reverberation time
  • Acoustic dose meter
  • Human Vibration measurements

Applications:

  • Sound measurements
  • Environmental noise
  • Building acoustic
  • Infrasound
  • High level/low level noise
  • Hand-arm vibration
  • Whole-body vibration
  • Machine vibration
  • Building/ground vibration

General Specification:

Input IEPE type (channels 1, 2, 3 - LEMO 4-pin & channel 4 - TNC connector)
Dynamic Range 100 dB, 4 x 20 bits A/D converters
Frequency Range 0.5 Hz ÷ 20 kHz, sampling rate 48 kHz
Memory 32 MB non-volatile flash type, external USB memory stick (not included)
Display Colour 320 x 240 pixels, OLED type
Keyboard 9 Push Buttons
Communication Interfaces USB 1.1 Client
USB 1.1 Host
RS232 (with SV 55 option)
External I/O - AC output (1 V Peak) or Digital Input/Output (Trigger - Pulse)
Power Supply Four AA batteries (alkaline) or four AA rechargeable NiMH batteries (not included)
USB interface 500 mA HUB
External power supply 6 V DC ÷ 24 V DC (1.5 W)
SA 17A external battery pack (option)
Environmental Conditions Temperature from -10 oC to 50 oC
Humidity up to 90% RH, non-condensed
Dimensions 140 mm x 82 x 42 mm
Weight Approx. 0.5 kg with batteries

SVAN 958A Sound Level Meter Specification:

Standards Class 1: IEC 61672-1:2002
Number of Profiles 3
Weighting Filters A, B, C, Z, G
Time Constants Slow, Fast, Impulse
RMS Detector Digital True RMS detector with Peak detection, resolution 0.1 dB
Microphone (Option) MK 250, Class 1, 50 mV/Pa, prepolarised 1/2"e
Preamplifier (Option) SV 12L IEPE type
Linear Operating Range 26 dBA RMS ÷ 140 dBA Peak (in accordance to IEC 61672)
Total Dynamic Measurement Range 16 dBA RMS ÷ 140 dBA Peak (typical from noise floor to the maximum level)
Internal Noise Level less than 16 dBA RMS
Dynamic Range >100 dB
Frequency Range 3.5 Hz ÷ 20 kHz with MK250 microphone
Meter Mode Results SPL, Leq, SEL, Lden, LEPd, Overload time, Ltm3, Ltm5, LMax, LMin, LPeak,
Simultaneous measurement in three profiles with independent filters and detectors
Statistics Ln (L1-L99), complete histogram in meter mode, averaging: linear of with detector (exponential)
Ln (L1-L99) statistics in 1/1 or 1/3 octaves (if option is active)
Data Logger logging of summary results with step from 30 s (auto-save function)
logging of time history with step from 10 ms
Wave Recording (Option) Time domain signal recording during measurement, trigger or continuous mode, 12 / 24 / 48 kHz sampling rate, 16 or 24 bit, wav format

Sound Analyser:

1/1 Octave Analysis (Option) Real-time analysis meeting Class 1 requirements of IEC 61260, center frequencies from 31.5 Hz to 16 kHz (audio band), selectable weighting filter, detector linear or
Real-time analysis meeting Class 1 requirements of IEC 61260, center frequencies from 1 Hz to 16 kHz (full band), selectable weighting filter, detector linear
1/3 Octave Analysis (Option) Real-time analysis meeting Class 1 requirements of IEC 61260, center frequencies from 20 Hz to 20 kHz (audio band), selectable weighting filter, detector linear
Real-time analysis meeting Class 1 requirements of IEC 61260, center frequencies from 0.8 Hz to 20 kHz (full band), selectable weighting filter, detector linear
FFT Analysis (option) 480 or 960 or 1920 lines in selectable band from 87.5 Hz to 22.4 kHz with selectable weighting filter, linear averaging, selectable window
RT 60 (Option) Reverberation time analysis in 1/3 octaves, selectable method: decay or impulse
RPM (Option) Rotation measurement option without Laser Tachometer (option), measurement of RPM, RPS, RMAX, RMIN
Cross Spectrum (Option) Transfer Function and Coherence calculation
Sound Intensity (option) FFT - based sound intensity calculation

Vibration Level Meter:

Standards ISO 8041:2005, ISO 10816-1
Number of Profiles 1 or 2 in Ground Vibration mode
Weighting Filters Wd, Wk, Wc, Wj, Wm, Wb, Wg (ISO 2631), Wh (ISO 5349), HP1, HP3, HP10, Vel1, Vel3, Vel10, VelMF, Dil1, Dil3, Dil10, KB (DIN 4150)
RMS Detector Digital True RMS detector with Peak detection, resolution 0.1 dB
Time constants: from 100 ms to 10 s
Meter Mode Results RMS, MAX, Peak, Peak-Peak, Overload time, MTVV, VDV, CRF,
Accelerometer (Option) SV 84 triaxial high sensitivity accelerometer for ground or building vibration measurements (1 V/g)
SV 38 triaxial accelerometers for whole-body measurements (1 V/g MEMS type)
Measurement Range with SV 84: 0.0005 ms-2 RMS ÷ 50 ms-2 PEAK
Frequency Range 0.5 Hz ÷ 20 kHz; accelerometer dependent

Vibration Analyser:

Ground Vibration (Included) 2 vibration profiles for simultaneos measurement of PPV and VDV, simultaneous FFT analysis (if option active), simultaneous WAVE recording (if option active) according to DIN 4150-3 standard
1/1 Octave Analysis (Option) Real-time analysis meeting Class 1 requirements of IEC 61260, center frequencies from 1 Hz to 16 kHz (full band), HP weighting filter, detector linear
1/3 Octave Analysis (Option) Real-time analysis meeting Class 1 requirements of IEC 61260, center frequencies from 0.8 Hz to 20 kHz (full band), HP weighting filter, detector linear
FFT Analysis (Option) 480 or 960 or 1920* lines in selectable band from 78 Hz to 20 kHz with HP weighting filter, averaging: linear , and selectable window
*1920 lines not available for time history logging, minimum 50ms step for time history logging with 960 lines, minimum 20ms step for time history logging with 480 lines
RPM (Option) Rotation measurement option without Laser Tachometer (option), measurement of RPM, RPS, RMAX, RMIN
Cross Spectra (Option) Transfer Function and Coherence calculation

What's in the Box

  • Svan 958A 4 Channel Sound & Vibration Meter
  • SC 16 USB cable, SC 61, 4 x AA batteries,
  • CD with instruction, transducers not included

Software

About SvanPC++

This piece of advanced software supports Svantek measuring instruments. Each Svantek device is is easy to use and a complete measuring systems because of the functionalities and extended capabilities in this advanced application. The software has been divided for several specialised modules by distinguishing application fields in order to give users the perfectly customised, powerful and sophisticated tool. The functions provided by the main module include measurement data downloading from instruments to PC, measurement setups creating, basic Leq/RMS recalculation, measurement results in text, tabular and graphical format, export data to spread sheets or text editor applications.

Features include:

  • Being able to easily download data of measurements to a PC
  • Total Leq/ RMS recalculation
  • Quick reporting tool
  • A variety of presentation results including text, table and graphical format 
  • Advanced customisation of each view
  • Creation of measurement setups  
  • Merging of measurement files.
Write Your Own Review