This general purpose Castle noise and vibration kit incorporates both the Exilis GA2008 and the Castle SONUS GA116I.
The Exilis GA2008 Vibration Meter is a simple to use instrument, ideal for measuring acceleration, velocity and displacement. Ideal for checking fixed monitoring systems, condition maintenance prediction and other engineering operations.
The Castle SONUS GA116I is a feature packed instrument that is fully compliant with IEC 61672-1:2013 Class 1, and IEC61252: 1993. This meter gives simultaneous Leq (rms. average) personal exposure (LEpd) and peak measurement for assessments to the Control of Noise at Work Regulations 2005. It has a high-specification, Class 1 measurement microphone and is cased in tough, crack resistant ABS plastic. For compliance with the Control of Noise at Work Regulations 2005, the Sonus provides you with everything you need to assess Noise in the workplace.
Measurement Parameters | Dose, Lepd, Leq, Le, Peak, Lmax, Lspl, Noise Exposure Pa2h |
---|---|
Class | Class 1, Class 2 |
Weightings | A, C |
Application | Noise at Work, Environmental Noise |
Brand | Castle Group |
Available Outside the UK? | Yes |
This Noise and Vibration System kit incorporates 2 of Castles portable meters to monitor vibration, noise at work and environmental sound monitoring. Also included in the kit is the MK79 Dosemeter Plug-in Microphone, GA607 Calibrator and small kit case.
The Exilis GA2008 is a robust vibration meter capable of monitoring many types of vibration with excellent accuracy.
The small design of the Exilis means it is easily portable which allows it to be able to take vibration readings in any area with a vibration problem and store it in it's data logging system.
The uses for this instrument are far-reaching and widespread. One prime example would be a maintenance operator verifying results from a fixed monitoring system or taking measurements for maintenance prediction. Another example is a construction engineer checking that the vibration from a piling operation is not exceeding any environmental thresholds.
The Castle SONUS range of pocket sized sound level meters bring simplicity and power to the worlds of Noise at Work and Environmental sound monitoring. From a basic sound pressure meter to a combined sound and dosemeter, the range of systems covers a wide diversity of applications. The Castle SONUS GA116I is a feature packed instrument that is fully compliant with IEC 61672-1:2013 Class 1, and IEC61252: 1993. This meter gives simultaneous Leq (rms. average) personal exposure (LEpd) and peak measurement for assessments to the Control of Noise at Work Regulations 2005. It has a high-specification, Class 1 measurement microphone and is cased in tough, crack resistant ABS plastic.
GA2008
Applicable Standards | IEC 61672-1:2013 (Integrating, Sound Exposure and Sound Level Meters) IEC 60651:2001 (Sound Level Meters) IEC 60804:2000 (Integrating Function) |
Microphone and Preamplifier | Type 7146A Pre-Polarised ½” (13.2 mm) Free-Field, Electret Condenser Microphone: 20Hz – 20KHz ± 2dB –32 dB ± 3 dB re 1V/Pa Custom pre-amplifier design Typical actuator to free-field correction factor (based on 500Hz=0) is shown below |
Display | Back-lit LCD panel (8x1 Characters) Alpha-Numeric display for measured results |
Level Range | Total Measuring Range: 41-140 Linear operating range (IEC61672-1): 65dB 3 3 Display Ranges (IEC61672-1): 35-100 55-120 - Reference Range 75-140 |
Noise Floor | Typical ’A’ Weighting ‘C’ Weighting |
Frequency Weighting | ‘A’ and ’C’ to IEC 61672-1:2002 and IEC 60651:2001 |
Frequency Range | 12.5 Hz - 20 kHz (including microphone) 1 Hz - 20 kHz (electrical characteristics) |
Time Weighting | Slow and Fast |
Instrument Response | Simultaneous rms. and Peak |
Measurement Response | Lp (Sound Pressure Level), Leq (Equivalent Sound Level), Lmax (maximum Level), Cpeak (Max. Peak Level), LEpd (Sound Exposure Level), LAE (Single Event Sound Exposure Level) Other Displays: Elapsed time, Overload, Battery Life |
Calibration | Software controlled 91.0 to 120.0 dB (1kHz) in 0.1 dB steps |
Processing | A to D Converter: 12-bit Controller: 8MHz, micro-controller |
Output | AC Output = 16.4mVrms at 94dB (un-weighted and not affected by range) DC Output = 40mV/dB (weighted and ranged) |
Power Requirement | Batteries: 1 x 6LR61 (size PP3), Life: >12 hours (alkaline batteries, continuous operation) |
Size | Dimensions: 60mm (width) x 30mm (depth excluding pocket clip) x 135mm (height without microphone) or 210mm (height with microphone) |
Weight | 200gms (without battery) |
Manuals | Multi-language manuals*: French, German, Spanish and Italian |
GA116I
Accelerometer | 100mV/g ±20% |
Acceleration Range | 0.01 to 100g |
Velocity Range | 0.1 to 1000 mm/s |
Displacement | 0.1 to 1000μm (Above in RMS or Peak and in 2 ranges) |
Mechanical Filter Frequency | 10Hz - 1KHz |
Linear Filter Frequency | 10Hz - 10KHz |
Memory | non-volatile E2PROM memory which holds calibration data plus storage of 9 spot results. |
Keypad | 9 Key Tactile Keypad |
Standards | Compliance with EMC CE marking |
Display | 8 Character LCD Display |
Intergration | Acceleration, Velocity, Displacement |
Filters | Mechanical & Linear |
Detectors | RMS and Peak |
Parameters | Average, max |
Overload Indication | (Flashing alternate display) |
Battery Indicator | 4 Bar Representation |
Weight | 250g with batteries |
Size | 135 x 62 x 30mm |
Batteries | 1 x IEC No 6LR61 (Upto 40 hrs life with Duracel MN1604) |
This Kit Includes: