We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies.
The POWER version of the E-Box is designed with endurance in mind. You are able to customise your power supply and even add Solar Power for any longer-term measurements, so you can rest assured this E-Box gives you the power you need to perform!
Application | Environmental, Environmental Noise |
---|---|
Features | Self Contained, Data Logger, Single Input, IP Rating |
Measurement Parameters | Ln, Leq, Le, Peak, Lden, Lmax, Lnight, Lmin, Lday |
Class | Class 1, Class 2 |
Weightings | A, C, Z |
Application | Environmental Noise, Long Term Noise Monitoring |
Noise Features | 1/3 Octaves, 1/1 Octaves, Statistics, Audio Events Recording, Weatherproof, Data Logging, USB Connectivity, Multi-Language, Voice Memo Recording |
Brand | Castle Group |
Available Outside the UK? | Yes |
When you need to perform unattended noise measurements that are to be left outdoors, the very last thing you need is the hassle of complicated equipment.
Castle's E-Box provides an effective and powerful Noise Monitor that's ready for you to use to its full capabilities - Straight Inside The Box
• Environmental Assessments
• Construction Noise
• Boundary Noise Monitoring
• Compliance Testing
• Handheld Noise Assessments
• Short Term Noise Assessments
• Long Term Noise Assessments
The POWER version of the E-Box is designed with endurance in mind. You are able to customise your power supply and even add Solar Panels for any long-term measurements, so you can rest assured this E-Box gives you the power you need to perform!
Applicable Standards | IEC 61672-1:2013 IEC 61260-1:2014 (Where Octave Bands Fitted) IEC 61252:1993 amendment 1:2000 (Where Exposure Fitted) |
Microphone |
Class 1:Type 1 Pre-Polarised ½” (50mV/Pa) Condenser Microphone -26 dB ± 2 dB re 1V/Pa Class 2:Type 2 Pre-Polarised ½” (25mV/Pa) Condenser Microphone –32 dB ± 3 dB re 1V/Pa |
Measurement Ranges | Linear Operating Range: 95dB |
Noise Floor | Typical ’A’ WeightingFrequency WeightingsMeasurement 1: A, C or Z Measurement 2: A, C or Z |
Frequency Range | 1 Hz - 20 kHz (electrical characteristics) Class 1: 12.5 Hz - 20 kHz (including microphone) Class 2: 16Hz - 16kHz (including microphone) |
Time Weighting | Measurement 1: Slow, Fast, Impulse Measurement 2: Slow, Fast, Impulse |
Display | 2.4” Full Colour TFT 240x320 pixels |
Dual Measurements | Simultaneous dual measurement with independent time and frequency weightings |
Octave Band Analysis | Where fitted 1/1 or 1/3 octave band analysis on measurement 1 only. |
dBAir Environmental | LSPL, LE, LEQ, LMAX, LMIN, Peak, Ltm3, Ltm5, Lday, Lnight, Ldn, Lden, NA, 10 user-definable Ln values (pre-set to: L1, L2, L5, L10, L50, L90, L95, L98, L99) plus LAF* for Noise act assessment. |
dBAir Environmental Octave: | LSPL, LE, LEQ, LMAX, LMIN, Peak, Ltm3, Ltm5, Lday, Lnight, Ldn, Lden, NA, 10 user-definable Ln values (pre-set to: L1, L2, L5, L10, L50, L90, L95, L98, L99) plus LAF* for Noise act assessment. 1/1 or 1/3 Octaves: LSPL, LE, LEQ, LMAX, LMAX, Ln’s, Peak. 1/3 Octaves. |
dBAir Safety & Environmental | LSPL, LE, LEQ, LMAX, LMIN, Peak, LEP’d, Exposure Points, Dose, Hearing Protector Calculator, Ltm3, Ltm5, Lday, Lnight, Ldn, Lden, NA, 10 user-definable Ln values (preset to: L1, L2, L5, L10, L50, L90, L95, L98, L99) plus LAF* for Noise act assessment. |
dBAir Safety & Environmental Octave: | LSPL, LE, LEQ, LMAX, LMIN, Peak, LEP’d, Exposure Points, Dose, Hearing Protector Calculator, Ltm3, Ltm5, Lday, Lnight, Ldn, Lden, NA, 10 user-definable Ln values (pre-set to: L1, L2, L5, L10, L50, L90, L95, L98, L99) plus LAF* for Noise act assessment. 1/1 or 1/3 Octaves. |
Languages | English UK, English US, Chinese, French, German, Italian, Portuguese Brazilian, Russian, Spanish. |
Time History | Short Interval: 10ms to 60m Long Interval: 1s to 24h Smart Timer, Duration Timer or Interval Timer Memory 16GB, 32GB, 64GB Input / Output Connection Micro USB Type B |
|
The E-Box POWER Systems are available with a choice of Class 1 or Class 2 accuracy, measurement parameters and power options. Each system also includes the following: |
GA611 or GA612 | dBCal 3-level Acoustic Calibrator, Class 1 or Class 2 (sound meter class dependant) |
CCST03 | Standard Account for Castle Cloud - 10 Users, 10 Instruments (13Year) |
MW404A | Weatherproof Microphone Housing (Sonik/dBAir) |
ZL2141-03 | Weatherproof Case Microphone Cable for Sonik/dBAir - 3m |
KA02XX | E-Box POWER case for dBAir (power source dependant) |
KA020RS | E-Box Accessory Rucksack |
EBOXMOUNT | Integrated Microphone Mounting Kit for E-Box |
Download English Manual: dBAir Sound Level Meter Brochure
Download Brochure in English: dBAir Sound Level Meter Manual
Download Brochure in Spanish: dBAir Sound Level Meter Brochure in Spanish
With secure Cloud software at TheCastleCloud.com you can securely access your data from any internet browser on any device. TheCastleCloud is a feature packed noise analysis software system, with added benefits:
Find out more at TheCastleCloud.com
PC, Mac, Tablet or phone, you can access your account and data from any device, anywhere in the world!
Not only do we regularly back-up all your data onto secure servers, you can also download your own data at any time onto your device.
As soon as you log into your Castle Cloud account, your data will be waiting for you primed for analysis and report creating. Alternatively, use a USB cable to copy a csv file straight off the meter!
Set Administration Levels for different staff, ensuring the safety of your data whilst ensuring you get the most out of your results.
Cloud softare isn't just the future, it's the present! If you use Apple, Dropbox, Microsoft or Google then you're already on the cloud and benefiting from the power and flexibility that brings.